Mecer ME-3000-WPRU 3000VA ON-LINE Rackmountable (with Monitoring Software) Uninterruptible Power Supply Black. 12 V / 9 Ah batteries x6. Voltronic Power Winner Pro online pure sine wave UPS
With enough juice to keep your machines going long enough to ensure they can be safely turned off this, this Mecer ME-3000-WPRU uninterruptible power supply comes with AVR, monitoring software, a built in cable and surge-protection already installed.
Key Features of the Mecer ME-3000-WPRU UPS
â—‹ ONLINE UPS
â—‹ True double-conversion
â—‹ Microprocessor control optimizes reliability
â—‹ Input power factor correction 0.99
â—‹ Output power factor 0.8
○ Wide input voltage (110 V–300 V)
â—‹ Converter mode available
â—‹ ECO mode for energy saving
â—‹ Generator compatible
â—‹ Adjustable battery numbers only available for 6K and up models
â—‹ Smart SNMP works well with either USB or RS-232 together
â—‹ Emergency power off function only available for 6K and up models
Specifications of the Mecer ME-3000-WPRU UPS
Specifications and features | |
Product Code | ME-3000-WPRU |
CAPACITY | 3000 VA / 2400 W |
PHASE | Single phase with ground |
INPUT | |
Input Voltage Range | 55-150 VAC or 110-300 VAC (Based on load at 50%); 85-140VAC or 160-280VAC (Based on load at 100%) |
Nominal Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
Frequency Range | 40Hz ~70 Hz |
Power Factor | >= 0.99 @ Nominal Voltage (100% load) |
OUTPUT | |
Voltage Regulation | ± 1% |
Output Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz |
Transfer Time : AC Mode to Battery Mode | Zero |
Transfer Time : Inverter to Bypass | 4 ms (Typical) |
Transfer Time : Waveform (Batt. Mode) | Pure Sine Wave |
Current Crest Ratio | 3::1 |
Harmonic Distortion | — 3% THD (Linear Load); — 6% THD (Non-linear Load) |
Frequency Range (Synchronized Range) | 47~53 Hz or 57~63 Hz |
EFFICIENCY | |
Battery Mode | 0.88 |
AC Mode | 0.9 |
BATTERY | |
Long-run Model : Battery Type | Depending on the capacity of external batteries |
Long-run Model : Charging Current (max.) | 1A/2A/4A/6A (Adjustable) |
Long-run Model : Charging Voltage | 82.1 VDC ± 1% ,109.4 VDC ± 1% |
Long-run Model : Numbers | 6, 8 |
Standard Model : Battery Type | 12 V / 9 AH |
Standard Model : Charging Current (max.) | 1A |
Standard Model : Charging Voltage | 82.1 VDC ± 1% |
Standard Model : Numbers | 6 |
Standard Model : Typical Recharge Time | 4 hours recover to 90% capacity |
INDICATORS | |
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
ALARM | |
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
ENVIRONMENT | |
Operating Humidity | 20~90% RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 50dB @ 1 Meter |
PHYSICAL | |
Standard Model : Dimension, D x W x H (mm) | 630 x 438 x 88 [2U] |
Standard Model : Net Weight (kgs) | 29.3 |
Long-run Model : Dimension, D x W x H (mm) | 410 x 438 x 88 [2U] |
Long-run Model : Net Weight (kgs) | 14.2 |
MANAGEMENT | |
Optional SNMP | Power management from SNMP manager and web browser |
Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |